Skip to main content

Table 1 Descriptive statistics and statistical comparisons (independent samples t-test) of the surface roughness and waviness measurements between enamel undergone the complete IPR oscillating system (Group 1) and enamel treated with single oscillating metallic strip (Group 2)

From: Effects of IPR by mechanical oscillating strips system on biological structures: a quantitative and qualitative evaluation

Variables

Enamel after IPR sequence

 

Enamel after single strip

 

Comparison

 

95% CI of the difference

 
 

Mean

SD

Mean

SD

Diff.

P value

Lower

Upper

Ra (µm)

0.45

0.04

0.79

0.08

0.34

0.000

− 0.01

0.91

RSm (µm)

0.02

0.01

0.03

0.02

− 0.01

0.185

− 0.09

0.11

Rt (µm)

4.57

0.58

6.12

0.82

− 1.55

0.000

3.46

− 10.24

Wa (µm)

2.16

0.13

1.91

0.16

− 0.25

0.000

− 3.31

2.95

Wt (µm)

11.58

1.73

7.56

0.66

− 4.02

0.000

− 0.172

1.118