Table 9 Stresses in the implant in group I and group II consolidated and non-consolidated models

From: Evaluating the effects of consolidation on intrusion and retraction using temporary anchorage devices—a FEM study

   Max von Mises stress in consolidation Max von Mises stress in non-consolidation Max principal stress in consolidation Max principal stress in non-consolidation
Group I 7 mm 108.4 108.7 116 116.2
10 mm 106.6 106.9 116.2 116.5
13 mm 106.1 106.4 109.5 109.8
Group II 7 mm 135.1 135.1 144.5 144.5
10 mm 106.6 106.9 116.2 116.6
13 mm 106.1 106.4 109.5 109.8
  1. Group I: Von Mises stresses are high in 7-mm implant height, and principle stresses are more in 10-mm implant height in consolidation and non-consolidation
  2. Group II: Von Mises stresses and principle stresses are high in 7-mm implant height in consolidation and non-consolidation