From: Comparison and evaluation of stresses generated by rapid maxillary expansion and the implant-supported rapid maxillary expansion on the craniofacial structures using finite element method of stress analysis
Material
Modulus of elasticity
Poisson’s ratio
Compact bone
1.37 × 103
0.3
Cancellous bone
7.9 × 102
Tooth
2.0 × 103
Sutures
1.46Â MPa
0.28
Cartilage
0.69Â MPa
0.018
Titanium
114Â MPa
0.34