Skip to main content

Table 1 Characteristics of the included studies

From: Effectiveness of en masse versus two-step retraction: a systematic review and meta-analysis

Study info.

Study design

G

Sample no.

Age

Gender

Malocclusion

Archwire/bracket

Anchorage and Aux

Force system/amount

Measurement T

Al-Sibaie and Hajeer 2013 [18]

RCT

G1

28

23.02

19F/9M

Class II div. 1/OJ > 5 Crowding <3.5

0.019 × 0.025″ SS/0.022″ MBT

Miniscrews

Elastic-chain 150 g

T1 before ttt/T2 after leveling/T3 class I canine

G2

28

20.46

16F/12M

0.019 × 0.025″ SS/0.022″ MBT

TPAs

Elastic-chain

Davoody et al. 2012 [20]

RCT

G1

23

17.4 SD 8.8

6F/7M

Angle class I or II

0.016 × 0.022″ SS/0.022″ slot SL

Miniscrews

NiTi coil 150 g

T1 before retraction

G2

23

17.9 SD 8.9

10F/5M

0.016 × 0.022″ SS/0.022″ slot SL

Differential moment

NiTi coil 150 g (canine) then 0.017 × 0.025 SS loop (incisors) and 0.017 × 0.025 NiTi intrusion arch

T2 after retraction

Huang et al. 2010 [24]

Prospective

G1

26

15.4 SD 1.9

18F/8M

Class I or II

0.018 × 0.025″ SS/0.022″ slot

 

NiTi coil 150 g

T1 before space closure

G2

26

15.8 SD 1.8

18F/8M

0.018 × 0.025″ SS/0.022″ slot

 

NiTi coil 150 g (canine) then (incisors)

T2 after space closure

Kuroda et al. 2009 [23]

Prospective

G1

11

18.5 SD 3.3

F

Class II/ OJ > 5

 

Miniscrews

NiTi coil 100 g

T1 before ttt

G2

11

21.8 SD 7.9

F

 

TPA and HG

Sliding mechanics (canine) then loop mechanics (incisors)

T2 after ttt

Solem et al. 2013 [22]

Prospective

G1

11

20 to 29 mean 24 years

20F/4M

Angle class I/ severe dentoalveolar protrusion

0.016 × 0.022″ SS/0.018″ slot

Miniplates

Elastic-chain

T1 before ttt

G2

13

0.016 × 0.022″ SS/0.018″ slot

TPAs

Elastic-chain (canine) then intrusion retraction loop (incisors)

T2 after ttt

Upadhyay et al. 2008 [21]

Prospective

G1

15

14.5 to 22.3 mean 17.2

10F/5M

Angle class I/ class II div. 1 with severe OJ

0.017 × 0.025″ SS/0.022″ ROTH

Miniscrews

NiTi coil 150 g

T1 before retraction

G2

15

11F/4M

 

Nance, HG, Bond7

 

T2 after retraction

Upadhyay et al. 2008 [17]

RCT

G1

20

17.6years

F

OJ = <5/Crowding < 3.5

0.017 × 0.025″ SS/0.022″ ROTH

Miniscrews

NiTi coil 150 g

T1 before retraction

G2

20

17.3years

F

0.017 × 0.025″ SS/0.022″ ROTH

TPA, HG, Bond7

 

T2 after space closure

Xu et al. 2010 [19]

RCT

G1

32

12.6 SD 1.1

20F/12M

Class I or II

0.022″ MBT

32 HG/27 TPA

Active laceback

T1 before ttt

G2

32

12.7 SD 1.2

19F/12M

0.022″ MBT

31 HG/21 TPA

Active laceback

T2 after ttt

  1. G group, Aux auxiliaries, T time, RCT randomized controlled trial, OJ overjet, ttt treatment, SS stainless steel, SL self-ligation, HG headgear, TPA transpalatal arch