Skip to main content

Table 3 Comparison of displacement between RME and I-RME

From: Comparison and evaluation of stresses generated by rapid maxillary expansion and the implant-supported rapid maxillary expansion on the craniofacial structures using finite element method of stress analysis

Site

RME

Implant-supported RME

“X”

direction (mm)

“Y”

direction (mm)

“Z”

direction (mm)

“X”

direction (mm)

“Y”

direction (mm)

“Z”

direction (mm)

Midpalatal suture

4.47

3.40

1.48

0.555

2.132

−1.242

Naso-maxillary suture

3.55

1.54

0.24

0.788

1.715

0.110

Zygomatico-maxillary suture

3.59

0.21

0.44

3.017

3.462

2.184

Pterygo-maxillary suture

4.64

1.01

0.58

1.119

2.127

1.612

Intranasal suture

0.392

1.80

−0.67

−0.72

2.28

0.045

Fronto-maxillary suture

1.53

1.18

0.03

0.12

2.39

0.45

Naso-frontal suture

0.54

1.14

0.001

−0.73

1.46

0.15

Zygomatico-temporal suture

0.78

0.49

1.38

−0.227

0.306

1.919

Zygomatico-frontal suture

0.19

0.68

1.09

0.43

1.02

1.57

Spheno-occipital synchondrosis

0.00002

0.002

0.0001

0.116

0.580

0.535

  1. X direction, Negative value denotes lateral displacement; positive denotes medial displacement
  2. Y direction, Negative value denotes posterior displacement; positive denotes anterior displacement
  3. Z direction, Negative value denotes superior displacement; positive denotes inferior displacement