Table 7 Avg. of mesial and distal temperature rise during IPR

From: Evaluation of temperature rise in the pulp during various IPR techniques—an in vivo study

During IPR Avg. Temp.
Group N Mean Std. deviation 95% confidence interval for mean
Lower bound Upper bound
1 17 38.671 .8644 38.226 39.115
2 17 37.329 .4661 37.090 37.569
3 17 38.141 .2830 37.996 38.287
P value < 0.0001
Post hoc pairwise comparison Gr 3 < Gr 2 < Gr 1
\